7/25/2010

Surgery: Pulmonary atresia - VSD, MAPCAs, Unifocalization

Staged repair of tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries. Duncan, BW., Mee, RBB, et al. JTCVS 2003;126:694-702.




Bill Brawn group: JTCVS 2004;127:251-8
Treatment algorithm:

Survival after first surgery:

Freedom from reintervention (surgery or cath) after complete repair:

Frank Hanley group re: Surgical creation of "A-P window"
Rodefeld, MD. et al. JTCVS 2002;123:1147-54.
Selection criteria for surgical creation of A-P window:
1) Presence of centrally confluent pulmonary arteries (1 - 2.5 mm in diameter with well-developed peripheral arborization)
2) Multiple, hypoplastic AP collaterals that communicated with true pulmonary artery system
3) Presence of marked cyanosis
Avoid this procedure in the following situations:
1) High flow from MAPCAs
2) Isolated supply from MAPCAs (indicates native PAs do not have good peripheral arborization...to stand the high flow-high pressure from aorta)
3) Native PAs > 2.5 mm and
4) non-confluent native PAs.

Frank Hanley group: (Circulation 2000)
V. Mohan Reddy et al. Circulation 2000;101:1826-32
Early and Intermediate outcomes after repair of pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries.
Treatment algorithm


Also see:

Journal Club: PA-VSD, MAPCAs, Unifocalization

MAPCAs in PA-VSD

Preop Evaluation of PAs in PA-VSD

7/23/2010

Anatomy: Preop. evaluation of pulmonary arteries/MAPCAs in Pulmonary Atresia - VSD

Review article

1) McGoon ratio:
(Diameter of RPA/DAo + Diameter of LPA/DAo)
Normal 2.1
Adequate for VSD closure 1.2
Inadequate <0.8 for VSD closure

2) Nakata Index:
(CSA of RPA + CSA of LPA)/BSA
Normal value > 200 mm2/m2
> 150 mm2/m2 is adequate.
(Not usable preoperatively when MAPCAs are the major source of PBF & one-stage unifocalization + full repair is planned).
(> 200 for single ventricle repair, > 100 for 2-ventricle repair...check correctness of this statement first)

3) Total Neo-Pulmonary Artery Index (TNPAI) = APC index + Nakata Index
APC index is the sum of CSA of all usable APCs/BSA
>250 - suitable for one-stage repair including VSD closure (These pts. have low RV/LV pressure ratio postoperatively).

Critique of all these indices: These indices consider only the size of proximal vessel and not consider the condition of distal parts of the vessels (which may be stenosed, etc).

Also see:
MAPCAs in PA-VSD
Surgical Outcome (Journal Club blog)
Surgical Treatment algorithm

7/22/2010

MAPCAs - Pulmonary Atresia with VSD

Theories on the nature/origin of MAPCAs in Pulmonary Atresia with VSD.

It is speculated that MAPCAs are enlarged bronchila arteries in whom the broncho-pulmonary anastamosis has enlarged.



(First 2 images are from MA Norgaard et al. Eur J Cardio-thorac Surg 2006;29:653-8)

Also see, on this subject:

Surgical outcome

Preop evaluation of PAs

7/20/2010

Cath: Parallax Error and Foreshortening

Image from The Cardiac Catheterization Handbook. Morton Kern. 3rd edition (1999):

Cross reference: Imaging VSD

Cath: X-ray


(Extract from Morton Kern’s The Cardiac Catheterization Handbook. 3rd edition 1999)

X-ray tube: converts electrical energy into X-ray beam. Electron beams from a heated cathode are accelerated towards the rotating disc of anode. The electrons become X-rays upon contact with anode. But, only 0.2-0.6% of electrical energy provided is eventually converted into X-ray. This process generates extreme heat.

Three factors influence the X-ray image:
1) Electrical current (mA): Number of photons (electrical particles) generated per second. Increasing milliamperage increases quality of image. But, heat generated is the limiting factor. Of course, this increases radiation exposure to patient and increases scatter – leading to increase in exposure to lab personnel.

2) Kilovoltage level (kV): The wavelength of the X-ray beam. Higher the kV, shorter is the wavelength. Less tissue penetration. So, for obese patients, high kV is needed to get adequate penetration. But, high kV leads to poor resolution of the image. Higher kV also increases scatter and therefore, higher exposure to lab personnel.

High kV - short wavelength, uniform and better penetration. But, low contrast in image.
Low kV - provides better contrast in image.

High kV allows to keep mA low, but the trade-off is low-contrast in the image. A balance has to be struck. kV has more effect on image contrast than mA.
3) Exposure Time (s): Pulse width

ICU - Shape of arterial line trace

Two simultaneous arterial line traces are displayed below:
One from right radial A line and the other from right femoral A line.
Guess which trace is from which line from the shape of the trace.
This is the uncropped image of the trace above, now has readings from these lines uncovered.
(Newborn, s/p coarctation repair and PA band)



7/14/2010

7/13/2010

Cath: Imaging VSD

Images from Kurt Amplatz's Radiology of Congenital Heart Disease (1992):



Cross reference: Parallax Error and Foreshortening