Oxygen Consumption in Children, measured during cardiac catheterization
Pediatric Cardiology 1996;17:207-13
825 measurements in 504 subjects (256 subjects were < 3 yrs old).
Using semi-open hood system with paramagnetic oxygen analyzer.
The paper gives regression formulas based on HR and BSA - for < 3 yrs and > 3yrs - boys and girls.